This specification IEC standards TECHNICAL 9. General This specification covers the design, manufacturing, testing, supply, delivery and performance requirements of three
PART 2: TECHNICAL 9. General This specification covers the design, manufacturing, testing, supply, delivery and performance requirements of three phase, 50 Hz, 11/0.416
5. Ratings are also standardised covering 132 kV and above and up to 765 kV class transformers and accordingly considered in this manual (Annexure 1.2). 6. List of
Contribute to jidafang2022/en development by creating an account on GitHub.
(Part 2/Sec 2) : 1979 3.6 kV Bushings, Section 2 Metal parts (Part 3/Sec 1) : 1988 17.5 kV Bushings, Section 1 Porcelain parts (Part 3/Sec 2) : 1988 17.5 kV Bushings, Section 2
TITLE : Technical Specification For 4000KVA, 33/0.433 kV Transformer(Oil Filled) Section-A SCOPE OF ENQUIRY 1.0 This specification covers the design,
TECHNICAL SPECIFICATION . FOR Outdoor type Distribution Transformers of 11 kV/433-250 V Class 200, 400, 630990 kVA 11 kV I 433-250V DISTRIBUTION
BID NO. 18-67 Page 1 of 30 TECHNICAL SPECIFICATIONS 28MVA, 115/12.47 kV Substation Power Transformer 1.4 STANDARDS The transformer shall be
PART 2: TECHNICAL 9. General This specification covers the design, manufacturing, testing, supply, delivery and performance requirements of three phase, 50 Hz, 11/0.416 kV distribution power transformers with accessories. All transformers shall have separate primary and secondary windings and be
5. Ratings are also standardised covering 132 kV and above and up to 765 kV class transformers and accordingly considered in this manual (Annexure 1.2). 6. List of applicable standards for transformer is enclosed for ready reference (Annexure 1.3). Guaranteed Technical Particulars for Power Transformers A. GENERAL Item
2012年11月19日FUNCTIONS OF TECHNICAL SPECIFICATIONS 1. “From an User perspective: To formally and fairly communicate exactly what the within the limitations of this standard”. Further, ‘Basis of MV.A’ is defined in section 7.2. IEEE standard C57.12.80-2010 clause 3.355 states the rating as follows:- “The rating of KV.A of a
and setting the transformer. 1.04 REFERENCES A. This specification provides the technical requirements for the design, manufacture and test of substation transformers. The service conditions shall be as specified in Usual Service Conditions section of C57.12.00. B. ANSI/IEEE C57.12.00 General Requirements for Liquid-Immersed
(Part 2/Sec 2) : 1979 3.6 kV Bushings, Section 2 Metal parts (Part 3/Sec 1) : 1988 17.5 kV Bushings, Section 1 Porcelain parts (Part 3/Sec 2) : 1988 17.5 kV Bushings, Section 2 Metal parts 8603:2008 Dimensions for porcelain transformer bushings for use in heavily polluted atmospheres,12/17.5 KV,24 KV and 36 KV ISS 5/1961 Specification for
BID NO. 18-67 Page 1 of 30 TECHNICAL SPECIFICATIONS 28MVA, 115/12.47 kV Substation Power Transformer 1.4 STANDARDS The transformer shall be designed, fabricated, and tested in accordance with this American National Standard for Transformers 230 kV and Below 833/958 through 8333/10417 kVA, Single-Phase,
order of 330 kV or 400 kV depending on the country. 1.2.1.2 Primary grid substations: These substations are located at the end of primary transmission lines and the primary voltage is stepped down to suitable secondary voltages of the order of 132 kV or 33 kV. 1.2.1.3 Secondary substations: The voltage is further stepped down to 11kV.
TECHNICAL SPECIFICATION FOR 40MVA, 132/33 KV POWER TRANSFORMER . Page 2 of 95 SECTION IV. TECHNICAL SPECIFICATION 1.0 SCOPE: 1.1 This Specification provides for design, engineering, manufacture, assembly, stage 2.0 STANDARDS: 2.1 All transformers and associated equipments and accessories shall,
TITLE : Technical Specification For 4000KVA, 33/0.433 kV Transformer(Oil Filled) Section-A SCOPE OF ENQUIRY 1.0 This specification covers the design, manufacture, inspectiontesting at manufacturer's works, proper packing, delivery to site and supervision of (installationcommissioning) and testing at BHEL ’s
1.2 SPECIFIC TECHNICAL REQUIREMENTS (STANDARD CONDITIONS) 1. Rated MVA (ONAN rating) 10 MVA 2. No. of phases 3 3. Type of Installation Outdoor 4. Frequency 50 Hz 5. Cooling medium Insulating oil 6. Rated voltage: a) High voltage winding b) Low voltage winding 33 KV 11 KV 7.. Highest continuous system voltage a) HV Side b) LV side 36
Technical Specification for 24kV Cable Entry Transformers Page 1 of 34 Specification ETS02-03-02 Ver 6 Ergon Energy Corporation Limited ABN 50 087 646 062 1. Purpose and Scope This Specification sets out the technical requirements for the design, manufacture, testing at works and delivery of 24 kV cable entry transformers Item No. Ergon Energy
TECHNICAL SPECIFICATION . FOR Outdoor type Distribution Transformers of 11 kV/433-250 V Class 200, 400, 630990 kVA 11 kV I 433-250V DISTRIBUTION TRANSFORMERS OF 200,400, 630990 A kV CAPACITTES WITH INTERNAL CSP (COMPLETELY SELF PROTECTED) recognized standard Specification for Power
1. of . 2. 11 kV XLPE 1 Core 150 mm2 No. Description Unit Specification Required Proposed . 1 . GENERAL . Manufacturer and country of origin To Be Filled Applicable Standards IEC60502-2IEC60228 Type To Be Filled Number of Cores Single/Three Single Voltage grade of cable Vo/V (Vmax) kV 12/20 (24) Conductor cross section area
2022年11月7日Interlocks must prevent any unsafe operation of the switchgear and must ensure that the operator follows safe and logical sequence of switching device operations. Interlock arrangements must be as stated in 5.11 of IEC 62271-200. Title: Technical specification for construction of 33/11 kV 2×31.5 MVA power substations The
PART 2: TECHNICAL 9. General This specification covers the design, manufacturing, testing, supply, delivery and performance requirements of three phase, 50 Hz, 11/0.416 kV distribution power transformers with accessories. All transformers shall have separate primary and secondary windings and be
2012年11月19日FUNCTIONS OF TECHNICAL SPECIFICATIONS 1. “From an User perspective: To formally and fairly communicate exactly what the within the limitations of this standard”. Further, ‘Basis of MV.A’ is defined in section 7.2. IEEE standard C57.12.80-2010 clause 3.355 states the rating as follows:- “The rating of KV.A of a
and setting the transformer. 1.04 REFERENCES A. This specification provides the technical requirements for the design, manufacture and test of substation transformers. The service conditions shall be as specified in Usual Service Conditions section of C57.12.00. B. ANSI/IEEE C57.12.00 General Requirements for Liquid-Immersed
(Part 2/Sec 2) : 1979 3.6 kV Bushings, Section 2 Metal parts (Part 3/Sec 1) : 1988 17.5 kV Bushings, Section 1 Porcelain parts (Part 3/Sec 2) : 1988 17.5 kV Bushings, Section 2 Metal parts 8603:2008 Dimensions for porcelain transformer bushings for use in heavily polluted atmospheres,12/17.5 KV,24 KV and 36 KV ISS 5/1961 Specification for
order of 330 kV or 400 kV depending on the country. 1.2.1.2 Primary grid substations: These substations are located at the end of primary transmission lines and the primary voltage is stepped down to suitable secondary voltages of the order of 132 kV or 33 kV. 1.2.1.3 Secondary substations: The voltage is further stepped down to 11kV.
BID NO. 18-67 Page 1 of 30 TECHNICAL SPECIFICATIONS 28MVA, 115/12.47 kV Substation Power Transformer 1.4 STANDARDS The transformer shall be designed, fabricated, and tested in accordance with this American National Standard for Transformers 230 kV and Below 833/958 through 8333/10417 kVA, Single-Phase,
TECHNICAL SPECIFICATION FOR 40MVA, 132/33 KV POWER TRANSFORMER . Page 2 of 95 SECTION IV. TECHNICAL SPECIFICATION 1.0 SCOPE: 1.1 This Specification provides for design, engineering, manufacture, assembly, stage 2.0 STANDARDS: 2.1 All transformers and associated equipments and accessories shall,
TECHNICAL SPECIFICATION . FOR Outdoor type Distribution Transformers of 11 kV/433-250 V Class 200, 400, 630990 kVA 11 kV I 433-250V DISTRIBUTION TRANSFORMERS OF 200,400, 630990 A kV CAPACITTES WITH INTERNAL CSP (COMPLETELY SELF PROTECTED) recognized standard Specification for Power
1.2 SPECIFIC TECHNICAL REQUIREMENTS (STANDARD CONDITIONS) 1. Rated MVA (ONAN rating) 10 MVA 2. No. of phases 3 3. Type of Installation Outdoor 4. Frequency 50 Hz 5. Cooling medium Insulating oil 6. Rated voltage: a) High voltage winding b) Low voltage winding 33 KV 11 KV 7.. Highest continuous system voltage a) HV Side b) LV side 36
A.11.18 Special Requirements for the 34.5/0.4 kV Distribution Transformers of ISWSs 131 A.11.19 Transport 132 A.12 34.5/0.4-0.231 kV and 30/0.4-0.231 Transformer Stations 132 A.12.1 Pole-Mounted Transformers 132 A.12.2 Ground-Mounted Transformers 133 A.13 Interposing Transformer 133 A.13.1 Scope 133 A.13.2 General 134 A.13.2.1
three-phase power transformer and enclosed secondary medium-voltage equipment. The following electrical ratings are typical: Primary voltage: 6.9–69 kV Transformer kVA: 500–20,000 kVA Secondary voltage: 2.4 kV–34.5 kV A primary unit substation is defined in the following standard: IEEE® Standard No. 100-2000
Technical Specification for 24kV Cable Entry Transformers Page 1 of 34 Specification ETS02-03-02 Ver 6 Ergon Energy Corporation Limited ABN 50 087 646 062 1. Purpose and Scope This Specification sets out the technical requirements for the design, manufacture, testing at works and delivery of 24 kV cable entry transformers Item No. Ergon Energy
3-Phase Distribution Transformers 11 or 33 kV/415-240V (Outdoor Type) 1. SCOPE: i) This specification covers design, engineering, manufacture, assembly, stage testing, inspection and testing before supply and delivery at site of oil immersed, naturally cooled 3-phase 11 kV/433 250 V and 33 kV/433-250 V distribution transformers for outdoor use.